Lesson 7 · Timber

Timber design: working with the grain

Timber grew to hold a tree up, not to be a beam, so it is strong along the grain and weak across it, it swells and shrinks with the weather, and it slowly sags under load that stays on. Timber design is about respecting all three.

Strong along the grain

Wood is a bundle of long hollow fibres running up the trunk. Pull or push along the fibres and they all work together; push across them and you only crush the hollow tubes; pull across them and you just peel the fibres apart. The result is a material whose strength depends hugely on direction.

grain runs this way along the grain (C24, MPa) bending24 compression21 tension14.5 across the grain compression2.5 tension0.4
Characteristic strengths of C24 softwood (EN 338). Along the grain it is a respectable structural material; across the grain, especially in tension, it is very weak.

So in timber you avoid tension across the grain (curved and notched beams, connections that split the wood), and check bearing stress across the grain where joists sit on supports.

Strength classes

Every piece of wood is different: knots, slope of grain and density all vary. Sawn timber is graded and sorted into strength classes such as C16, C24 and C30 for softwood (the number is the characteristic bending strength in MPa) and D30 to D70 for hardwood. Glued laminated timber, made from graded lamellae, comes as GL24h, GL28h and so on; it is more reliable because a weak spot in one lamella is backed up by its neighbours.

Moisture and load duration

Wood takes up and gives off water, and wetter wood is weaker and creeps more. Eurocode 5 sorts structures into three service classes: heated interiors (1), covered but unheated (2) and exposed to the weather (3).

Wood is also stronger under a brief load than a long one: it can carry far more for a few seconds than for fifty years. Both effects are combined in one factor, \(k_{\text{mod}}\), that scales the characteristic strength:

\[f_d = k_{\text{mod}}\, \frac{f_k}{\gamma_M}\]

For solid timber in service class 1 or 2, \(k_{\text{mod}}\) is 0.6 for permanent load, 0.8 for medium-term load (such as floor imposed load), 0.9 for short-term load (snow, in most places) and 1.1 for instantaneous load (a gust of wind). \(\gamma_M\) is 1.3 for solid timber and 1.25 for glulam.

Creep

Load that stays on keeps making timber deflect, for years. Eurocode 5 multiplies the instant deflection of each load by \((1 + k_{\text{def}})\), with \(k_{\text{def}}\) = 0.6 in service class 1, 0.8 in class 2 and 2.0 in class 3 for solid timber. Only the part of the imposed load that is there most of the time (the quasi-permanent part \(\psi_2 Q\)) creeps.

\[w_{\text{fin}} = w_{G}\,(1 + k_{\text{def}}) + w_{Q}\,(1 + \psi_2\, k_{\text{def}})\]

Worked example

C24 floor joist, 4 m span

50 × 200 mm joists at 400 mm centres in a heated house (service class 1). Floor finish and joists 0.5 kN/m², imposed load 1.5 kN/m² (\(\psi_2 = 0.3\)). C24: \(f_{m,k} = 24\ \text{MPa}\), \(E_{0,\text{mean}} = 11\ \text{GPa}\).

\[\begin{aligned} g &= 0.5 \times 0.4 = 0.20\ \text{kN/m}, \qquad q = 1.5 \times 0.4 = 0.60\ \text{kN/m} \\ w_{\text{ULS}} &= 1.35 \times 0.20 + 1.5 \times 0.60 = 1.17\ \text{kN/m} \\ M &= \frac{1.17 \times 4^2}{8} = 2.34\ \text{kN}\cdot\text{m} \\ W &= \frac{50 \times 200^2}{6} = 333\,000\ \text{mm}^3 \;\Rightarrow\; \sigma_m = \frac{2.34 \times 10^6}{333\,000} = 7.0\ \text{MPa} \\ f_{m,d} &= 0.8 \times \frac{24}{1.3} = 14.8\ \text{MPa} \;\Rightarrow\; \text{utilisation } 48\,\% \end{aligned}\]

Bending is easy. Now the deflection, with \(I = 50 \times 200^3/12 = 33.3 \times 10^6\ \text{mm}^4\):

\[\begin{aligned} w_G &= \frac{5 \times 0.20 \times 4000^4}{384 \times 11\,000 \times 33.3 \times 10^6} = 1.8\ \text{mm}, \qquad w_Q = 5.5\ \text{mm} \\ w_{\text{fin}} &= 1.8 \times 1.6 + 5.5 \times (1 + 0.3 \times 0.6) = 9.3\ \text{mm} \approx L/430 \end{aligned}\]

Typical limits are around L/250 to L/300, so this joist passes, but deflection and floor vibration, not strength, usually decide timber floor joists.

Engineered timber

Glulam, laminated veneer lumber (LVL) and cross-laminated timber (CLT) are made from smaller graded pieces glued together. They spread out the defects, come in sizes no tree could give, and CLT, with layers at right angles, works as a slab or wall carrying load in two directions. In fire, large timber sections char on the outside and the char protects the core, which is why heavy timber can perform well; see the fire engineering lesson.

Intuition

Treat timber like a bundle of drinking straws glued side by side: excellent along the straws, poor across them, and slowly squashed if you leave a weight on them.

Try it: the beam calculator has a C24 100 × 200 section preset.Open the beam calculator