Lesson 5 · Steel

Steel design: strong, slender and stable

Steel is so strong that steel members are usually slender, and slender members fail by buckling long before the steel yields. Steel design is mostly the study of stability.

Tension members

Tension is the easy case: pull a steel bar and it straightens itself. Its capacity is the smaller of yielding of the whole cross-section and fracture through the bolt holes:

\[N_{\text{pl}} = A f_y \qquad N_u = 0.9\, A_{\text{net}} f_u \quad \text{(Eurocode 3 form, before partial factors)}\]

Designers prefer yielding to govern, because yielding is ductile and fracture is not.

Compression and buckling

Push on a ruler and at some load it suddenly bows sideways. That is buckling, and it can happen at a stress far below yield. Euler found the critical load for a perfectly straight pin-ended column:

\[N_{\text{cr}} = \frac{\pi^2 E I}{(kL)^2}\]

\(kL\) is the effective length: the distance between points of zero moment in the buckled shape.

pin–pin k = 1.0 fixed–pin k ≈ 0.7 fixed–fixed k = 0.5 cantilever k = 2.0
The more the ends are restrained, the shorter the effective length and the higher the buckling load. These are theoretical values; codes recommend slightly larger ones for real connections.

Buckling happens about the axis with the smaller I, usually the weak axis of an I-section, unless that axis is braced.

From Euler to real columns

Real columns are not perfectly straight and contain residual stresses from rolling and welding, so they fail below both \(N_{\text{pl}}\) and \(N_{\text{cr}}\). Codes use a relative slenderness and a reduction factor χ read from a buckling curve:

\[\bar{\lambda} = \sqrt{\frac{A f_y}{N_{\text{cr}}}} \qquad N_b = \chi\, A f_y\]

Stocky columns (\(\bar{\lambda} < 0.2\)) reach yield; very slender ones approach the Euler curve; the interesting ones are in between.

Worked example

Buckling resistance of an HEA 200 column

Pin-ended, 4 m tall, S355, buckling about the weak axis: \(A = 53.8\ \text{cm}^2\), \(I_z = 1336\ \text{cm}^4\), \(E = 210\ \text{GPa}\).

\[\begin{aligned} N_{\text{cr}} &= \frac{\pi^2 \times 210\,000 \times 1336 \times 10^4}{4000^2} = 1731\ \text{kN} \\ N_{\text{pl}} &= 5380 \times 355 = 1910\ \text{kN} \\ \bar{\lambda} &= \sqrt{\frac{1910}{1731}} = 1.05 \end{aligned}\]

Eurocode 3 buckling curve c (imperfection factor \(\alpha = 0.49\)):

\[\begin{aligned} \Phi &= 0.5\left[1 + 0.49\,(1.05 - 0.2) + 1.05^2\right] = 1.26 \\ \chi &= \frac{1}{\Phi + \sqrt{\Phi^2 - \bar{\lambda}^2}} = 0.51 \\ N_{b,\text{Rd}} &= \frac{0.51 \times 1910}{1.0} \approx 977\ \text{kN} \end{aligned}\]

Buckling halves the column's capacity. Bracing it at mid-height about the weak axis would halve the effective length and roughly quadruple \(N_{\text{cr}}\).

Lateral-torsional buckling

A beam bent about its strong axis has a compression flange that behaves like a column: it wants to buckle sideways. Because the tension flange resists, the section twists as it moves. This is lateral-torsional buckling (LTB).

  • Its resistance depends on the unbraced length, the weak-axis stiffness \(EI_z\), the torsion constant \(GJ\) and the warping constant \(EI_w\).
  • Loads applied above the shear center (on the top flange) are destabilising; loads below it help.
  • The cure is simple: brace the compression flange with a slab, purlins or cross-members.
Intuition

A deep, narrow I-beam is efficient in bending but weak sideways. If you cannot brace it, choose a wider flange (an HEA or HEB instead of an IPE), or a box section, which is far stiffer in torsion.

Connections

Members are only as good as the joints between them. Bolts are checked for shear and bearing, welds for the stress through their throat, and plates for block tearing. A good connection is simple, ductile and buildable: it should yield in a plate or bolt before anything brittle happens.