Lesson 4 · Reinforced concrete

Reinforced concrete: two materials, one team

Concrete is strong in compression and weak in tension. Steel is strong in tension. Put the steel where the concrete would crack and you get one of the most versatile building materials ever made.

The big idea

Concrete cracks at a tensile stress of only about 10% of its compressive strength. In a reinforced concrete beam we simply assume the concrete in tension has already cracked and let steel bars carry all the tension. The concrete above the neutral axis carries the compression. Bond between the two makes them act together.

Flexure and the stress block

At failure, the real compressive stress in the concrete is curved. Codes replace it with an equivalent rectangular stress block of intensity \(0.85\,f'_c\) and depth \(a = \beta_1 c\), where c is the neutral axis depth (ACI 318; Eurocode 2 and TS 500 use the same idea with slightly different numbers).

section c (from top) 0.003εs strain \(0.85\,f'_c\)\(a = \beta_1 c\) C T = As·fy forces
Strain is linear (0.003 at the top at failure). The compression C and tension T form a couple with lever arm d − a/2.

If the steel yields, equilibrium \(C = T\) gives the block depth, and the couple gives the moment capacity:

\[a = \frac{A_s f_y}{0.85\, f'_c\, b} \qquad M_n = A_s f_y \left(d - \frac{a}{2}\right)\]

Worked example

Moment capacity of a rectangular beam

b = 300 mm, d = 450 mm, 3ø20 bars (\(A_s = 942\ \text{mm}^2\)), \(f'_c = 30\ \text{MPa}\), \(f_y = 420\ \text{MPa}\).

\[\begin{aligned} a &= \frac{942 \times 420}{0.85 \times 30 \times 300} = 51.7\ \text{mm} \\ M_n &= 942 \times 420 \times \left(450 - \frac{51.7}{2}\right) = 167.8 \times 10^6\ \text{N}{\cdot}\text{mm} = 167.8\ \text{kN}{\cdot}\text{m} \end{aligned}\]

Did the steel yield? \(\beta_1 = 0.836\) for 30 MPa, so \(c = a/\beta_1 = 61.9\ \text{mm}\).

\[\varepsilon_t = 0.003\,\frac{d - c}{c} = 0.003 \times \frac{388.1}{61.9} = 0.0188 \gg 0.005\]

The section is tension-controlled, so \(\phi = 0.90\) and the design strength is \(\phi M_n = 151\ \text{kN}{\cdot}\text{m}\).

Ductility and φ

A good beam fails slowly: the steel yields, cracks widen, the beam sags visibly, and people get out. A beam with too much steel fails suddenly by crushing the concrete first. Codes reward ductility:

  • Tension-controlled (\(\varepsilon_t \ge \varepsilon_y + 0.003\), about 0.005 for 420 MPa steel): \(\phi = 0.90\).
  • Compression-controlled (\(\varepsilon_t \le \varepsilon_y\)): \(\phi = 0.65\) for tied members, 0.75 for spirals.
  • In between, φ varies linearly.
Common mistake

Adding more steel does not always make a beam better. Past the balanced point it makes the failure brittle and lowers φ. Make the beam deeper instead.

Shear

Shear produces diagonal tension, which opens inclined cracks near the supports. The concrete itself resists part of the shear (\(V_c\), roughly \(0.17\sqrt{f'_c}\,b\,d\) in MPa units for simple cases), and stirrups crossing the cracks carry the rest:

\[V_s = \frac{A_v f_y\, d}{s} \qquad \phi V_n = 0.75\,(V_c + V_s) \ge V_u\]

Shear failures are brittle, so codes deliberately make them less likely than flexural failures, and earthquake codes require the beam to be stronger in shear than the shear it can develop in bending.

Columns and interaction

A column carries axial force and bending together, and the two interact. Compression initially helps bending capacity (it keeps cracks closed) until the concrete starts to crush. Plotting every combination of P and M the section can carry gives the interaction diagram:

  • Top: pure compression \(P_0 = 0.85\,f'_c\,(A_g - A_{st}) + f_y A_{st}\), capped in design at \(0.80\,\phi P_0\) for tied columns.
  • Balanced point: concrete crushes as the tension steel yields. Bending capacity peaks near here.
  • Bottom: pure bending, then pure tension.

Any load point \((P_u, M_u)\) inside the design curve is safe. Long columns also bend sideways under axial load, which magnifies the moment; check slenderness (\(k\,l_u/r\)) before trusting a short-column diagram.