Tool · Load combinations
Load combinations
Enter the effect of each load case at one location (a moment, an axial force or a reaction) and get every factored combination, with the governing maximum and minimum highlighted.
| Combination | Factors | Result |
|---|
About these combinations
ASCE 7-22 §2.3.1 strength design. Seismic combinations are simplified: E stands for the combined horizontal and vertical seismic effect, and the overstrength and redundancy factors are left to you. Combinations 3–4 are written out for each "or" choice.
EN 1990 Eq. 6.10 (STR/GEO set B) with the recommended factors: γG = 1.35 (1.0 when favourable), γQ = 1.5, and ψ₀ = 0.7 (imposed, categories A–D), 0.5 (snow), 0.6 (wind). The seismic case uses ψ₂ = 0.3 for imposed loads and 0 for snow and wind. Check your National Annex, which may change these values or require Eq. 6.10a/b instead.
TS 500 load factors with TBDY 2018 seismic combinations. E is the design earthquake effect including the 0.3 rule for the orthogonal direction and any vertical component. Snow enters the seismic combination with 0.2S; include it in Q for the other combinations if it acts as live load on your roof.
Tools are for learning and preliminary checks. Always verify designs against the governing code and have them reviewed by a qualified engineer.